Manual reset electronic pipe mounting adjustable limiter IP65
Applications
Pipes surface temperature alarm or high limit in usual industrial applications and environments. (No suitable for hazardous areas) Internal adjustment is convenient for products that must not be frequently adjusted.
Housing raw material | |
---|---|
Color | |
Ingress protection | |
Mechanical protection | |
Contact Material | |
Electrical rating | |
Voltage | |
Electrical life (cycles at rated value) | |
Measurement type | |
Sensing element | |
Temperature adjustment range (°C) | |
Differential (°C) | |
Setting adjustment |
Enclosure | Type | Operation | Contact | Measurement | Ranges °C | Models |
IP65, IK10 | Manual reset | Electronic | SPNC or SPNO | Pipe | Y102L
& Y112L |
|
Material |
||||||
Aluminum |
Applications
Pipes surface temperature alarm or high limit in usual industrial applications and environments. (No suitable for hazardous areas) Internal adjustment is convenient for products that must not be frequently adjusted.
Housing: Aluminum, IP65, IK10. Grey RAL7032 epoxy painting. Stainless steel captive cover screws. Captive aluminum lid.
Operation: Microprocessor manual reset electronic limiter, with adjustable set point. Adjustment ranges: 4-40°C (40-105°F); 30-90°C (85-195°F).
Set point adjustment: By °C printed knob. All types have an adjustable rotation limit system located inside the knob that allows reducing the set point adjustment span. Types with external adjustment have a transparent window. This device allows seeing the pilot light and the knob position. °F values are available as an option.
Reset: by push button switch beside the knob.
Sensing element: NTC sensor inside aluminum bracket in contact with the pipe surface. The bracket design provides optimized thermal contact with 34 mm (1 “, DN25), 60 mm (2″, DN50) and 90 mm (3”, DN80) outside diameter tubes. For intermediate sizes, we recommend the use of thermal grease.
Cable input and output: Two M20 cable glands, Black PA66. Internal electrical connection on screw terminals. 2 phase power supply (Line+ Neutral, 220~250V, 50Hz~60Hz) are mandatory.
Earthing: Internal and external screw terminal.
Pilot light: Allows to visualize thermostat contact output position. Standard for all models with transparent window. Non Standard and on special request only for models with plain aluminum cover.
Mounting: The thermostat housing can be fixed on the pipe by worm drive hose clamps (DIN3017) , nylon cable ties (Tie wraps upon EN50146, for applications at permanent temperature lower than 85°C), or specific stainless steel punched band (see accessories at the end of this catalog).
Identification: Metallic identification label, riveted.
Contact: SPST. 16A (2.6), 250VAC. Open or close on temperature rise. The version with contact closing on temperature rise is used to switch on an alarm. The version with contact opening on temperature rise is used to switch-off heating.
Electrical life: >100.000 cycles.
Minimum storage temperature: -35°C (-30°F)
Maximum ambient temperature: 60°C (140°F)
For more technical information ask 2PE2N6 thermostat technical data sheet.
Main references
Temperature adjustment ranges
°C (°F) |
Open on temperature rise contact | Close on temperature rise contact |
Max. temperature on tube°C (°F) |
||
Reference with external adjustment | Reference with internal adjustment | Reference with external adjustment | Reference with internal adjustment | ||
4-40°C (40-105°F) | Y112LN6F204040AJ | Y102LN6F204040AJ | Y112LN6G204040AJ | Y102LN6G204040AJ | 100°C (212°F) |
30-90°C (85-195°F) | Y112LN6F230090AJ | Y102LN6F230090AJ | Y112LN6G230090AJ | Y102LN6G230090AJ | 100°C (212°F) |
Downloadable
Datasheets
Related products
Remote temperature control boxes
Remote temperature limiter boxes
Remote temperature control boxes
Rod temperature limiter boxes
Rod temperature control boxes
Rod temperature limiter boxes
Pipe surface temperature limiter boxes
Room and antifreeze temperature control boxes
Technical informations associated to this product
-
General overview of JPC enclosures range
Temperature control of ambient, surface, air, liquids, pipes, by means of bulb and capillary, ambiance or rod probes. -
Electrical protection classes
The housings are designed to protect electrical equipment located inside. This protection must be considered in the electrical and environmental angles.) -
JPC Design concept of the Y1 types aluminum enclosures
Y1 range includes a wide range of thermostats in IP65* metal housing with high mechanical resistance (IK10** except models with external knob), intended for commercial or industrial applications covering ranges from -35 °C to +760 °C. -
Electrical contacts
As numerous mechanisms exist, we decided not to distinguish on the basis of constructive technique, but according to their operation speed, which is the key element.