Bulb and capillary thermostat IP44
IP44, black PC-ABS, fiberglass reinforced, UL94V0. High impact and UV resistance. 2 removable wall mounting lugs.
Housing raw material | |
---|---|
Color | |
Ingress protection | |
Contact style | |
Contact Material | |
Electrical rating | |
Voltage | |
Electrical life (cycles at rated value) | |
Measurement type | |
Sensing element | |
Differential (°C) | |
Setting adjustment |
Enclosure | Type | Operation | Contact | Measurement | Ranges °C | Models |
IP44 | Control | Mechanical | SPDT | Remote | Y038
& Y039 |
|
Material |
||||||
PC-ABS |
Housing: IP44, black PC-ABS, fiberglass reinforced, UL94V0. High impact and UV resistance. 2 removable wall mounting lugs.
Electrical input: One M20 cable gland.
Set point adjustment: By °C printed knob for external adjustment models, by screw driver and printed dial on internal adjustment models. °F values available as an option
Sensing element: Liquid filled bulb, distance measurement with capillary.
Temperature adjustment ranges: -35+35°C (-30+95°F), 4-40°C (40-105°F), 30-90°C (85-195°F), 30-110°C (90-230°F), 50-200°C (120-390°F), 50-300°C (120-570°F), 100-400°C (210-750°F), 100-500°C (210-930°F).
Electrical connections: 3 screw terminal connection block
Mounting: Wall mounting, by two side lugs with holes for dia. 4 mm screws, 63 mm distance.
Contact: SPDT
Electrical rating, resistive loads:
-Open on temperature rise contact (C-1) 16A 250V, 50 ~60Hz: >100000 cycles,
20A 250V, 50 ~60Hz: ≥ 50000 cycles,
10A 400V, 50 ~60Hz: ≥ 50000 cycles.
-Close on temperature rise contact (C-2) : 6A 250V 50 ~60Hz: >100000 cycles
Electrical rating, inductive loads:
-Open on temperature rise contact (C-1): 6A 250V, 50 ~60Hz: >100000 cycles
-Close on temperature rise contact (C-2):0.6A 250V 50 ~60Hz: >100000 cycles.
Minimum Storage temperature: -35°C (-30°F)
Maximum ambient temperature: 60°C (140°F)
For more technical information see 8G thermostat technical data sheet
Main references
Temperature | Internal adjustment | External adjustment | Bulb diameter (D, mm) | Bulb length (L, mm) | Differential°C (°F) | Max temperature on bulb °C (°F) |
-35+35°C (-30+95°F) | Y039GB-35035AO6J | Y038GB-35035AO6J | 6 | 98 | 1,6±1°C (2,9±2°F) | 55 (130) |
4-40°C (40-105°F) | Y039GB004040AO6J | Y038GB004040AO6J | 6 | 140 | 1±0.5°C (1,8±1°F) | 60 (140) |
30-90°C (85-195°F) | Y039GB030090AO6J | Y038GB030090AO6J | 6 | 87 | 2.5±1°C (4,5±1,8F) | 120 (250) |
30-110°C (90-230°F) | Y039GB030110AO6J | Y038GB030110AO6J | 6 | 93 | 2.5±1°C (4,5±1,8F) | 150 (300) |
50-200°C (120-390°F) | Y039GB050200AO6J | Y038GB050200AO6J | 6 | 59 | 4±2°C (7±3.6F) | 250 (480) |
50-300°C (120-570°F) | Y039GB050300AO3J | Y038GB050300AO3J | 3 | 145 | 10±5 (18±9) | 350 (660) |
100-400°C (210-750°F) | Y039GB100400AO3J | Y038GB100400AO3J | 3 | 93 | 10±5 (18±9) | 430 (800) |
100-500°C (210-930°F) | Y039GB100500AO4J | Y038GB100500AO4J | 4 | 235 | 10±5 (18±9) | 550 (1000) |
Downloadable
Datasheets
Related products
Room and antifreeze temperature control boxes
Electrical cabinet ambient temperature thermostats, Din Rail mounting
Remote temperature control boxes
Remote temperature control boxes
Remote temperature control boxes
Rod temperature control boxes
Remote temperature control boxes
Dia. 30 to 70mm pipe mounting thermostat IP55 with 2 built-in pilot lights
Remote temperature control boxes
Bulb and capillary thermostat IP55 with 2 built-in pilot lights
Bulb and capillary temperature limiters
Technical informations associated to this product
-
JPC Design concept of the Y0 types enclosures
The design of the Y0 enclosures was made to provide a starting range with a particular selection of low cost solutions. The plastic used is PC-ABC compound, with or without fiberglass reinforcement. -
Main properties of plastic raw materials used for enclosures
The classic housings, with only 5 sides and a lid, require a long and costly layout, most of the time ignoring the application needs: security, fire resistance, water penetration, shocks, UV, temperature, etc. -
Electrical protection classes
The housings are designed to protect electrical equipment located inside. This protection must be considered in the electrical and environmental angles.) -
Electrical contacts
As numerous mechanisms exist, we decided not to distinguish on the basis of constructive technique, but according to their operation speed, which is the key element.