Pigtail bulb room thermostat IP66, IK10
Applications
-Equipment requesting a very strong resistance to water ingress. The transparent cover allows to visualize the set point and the 2 pilot ligths
-Wall mounting for indoor or outdoor temperature control of cold rooms.
-Temperature control of industrial or commercial premises.
-Outdoor temperature control of antifreeze heaters.
-Green houses and livestock stables temperature control.
Housing raw material | |
---|---|
Color | |
Ingress protection | |
Mechanical protection | |
Contact Material | |
Electrical rating | |
Voltage | |
Electrical life (cycles at rated value) | |
Measurement type | |
Sensing element | |
Temperature adjustment range (°C) | |
Differential (°C) | |
Setting adjustment |
Enclosure | Type | Operation | Contact | Measurement | Ranges °C | Models |
IP66, IK10 | Control | Mechanical | SPDT | Ambient | YF7GNC | |
Material |
||||||
PA66 & PC |
Applications
-Equipment requesting a very strong resistance to water ingress. The transparent cover allows to visualize the set point and the 2 pilot ligths
-Wall mounting for indoor or outdoor temperature control of cold rooms.
-Temperature control of industrial or commercial premises.
-Outdoor temperature control of antifreeze heaters.
-Green houses and livestock stables temperature control.
Housing:Protection class IP 66 upon EN 60529 (waterproof spray water under high pressure and sea splashes, totally dust tight). Body in black PA66, fiber glass reinforced. The transparent polycarbonate cover can be unscrewed by hand, but it is also possible to use a hook spanner. Mechanical impact resistance : IK10. High UV resistance.
Set point adjustment: By °C printed knob. All types have an adjustable rotation limit system located inside the knob that allows reducing the set point adjustment span.°F printed knobs available as an option.
Action: Temperature control. On-Off action
Sensing element: Liquid filled “pigtail” stainless steel bulb, mounted on the top side of the plastic housing.
Pilot lights: One pilot light visualizes the thermostat contact output position. The other visualizes the power supply input. Phase and neutral electrical line supply are mandatory for these pilot lights.
Set point adjustment ranges:4-40°C (40-105°F)
Cable input and output:Two M20 cable glands, built-in black PA66.
Electrical connections:Inside, on screw terminal connection block. It is possible to connect 2 wires 1.5mm² on each terminal.
Earthing:Internal screw terminal.
Mounting:Wall mounting, by 2 legs with holes for screws dia. 4 to 5 mm, 114 mm distance
Identification:Identification label on backside.
Contact:SPDT
Electrical rating, resistive loads:
-Open on temperature rise contact (C-1) 16A 250V, 50 ~60Hz: >100000 cycles,
20A 250V, 50 ~60Hz: ≥ 50000 cycles,
10A 400V, 50 ~60Hz: ≥ 50000 cycles.
-Close on temperature rise contact (C-2): 6A 250V 50 ~60Hz: >100000 cycles
Electrical rating, inductive loads:
-Open on temperature rise contact (C-1): 2.6A 250V, 50 ~60Hz: >100000 cycles
-Close on temperature rise contact (C-2):0.6A 250V 50 ~60Hz: >100000 cycles.
Minimum storage temperature: -35°C (-30°F)
Maximum ambient temperature: 60°C (140°F)
For more technical information ask 8G thermostat technical data sheet.
Main references
Temperature adjustment ranges°C (°F) | Reference | Differential °C (°F) |
4-40°C (40-105°F) | YF7GNC04040023ZJ | 1,6±1°C (2,9±2°F) |
Downloadable
Datasheets
Related products
Rod temperature limiter boxes
Bimetal surface thermostats
Room and antifreeze temperature limiter boxes
Remote temperature control boxes
Room and antifreeze temperature control boxes
Fixed setting ambiance or antifreeze thermostat, IP65 cable gland output, two pilot lights
Rod temperature control boxes
Rod temperature limiter boxes
Technical informations associated to this product
-
Main properties of plastic raw materials used for enclosures
The classic housings, with only 5 sides and a lid, require a long and costly layout, most of the time ignoring the application needs: security, fire resistance, water penetration, shocks, UV, temperature, etc. -
Electrical protection classes
The housings are designed to protect electrical equipment located inside. This protection must be considered in the electrical and environmental angles.) -
Thermostats installation
The proper functioning of a thermostat depends primarily on the correct choice of the component, but also the conditions of its installation. Conditions used to calibrate regulating and control equipment in the factory are always ideal laboratory conditions, ensuring measurement accuracy and repeatability. These conditions are rarely those found in practice when installing thermostats. However, with a minimum of constraints, it is possible to optimize assemblies. -
Electrical contacts
As numerous mechanisms exist, we decided not to distinguish on the basis of constructive technique, but according to their operation speed, which is the key element.