Adjustable manual reset electronic room limiter IP66, IK10
– Equipment requesting a very strong resistance to water ingress. The transparent cover allows to visualize the set point and the 2 pilot lights.
- Wall mounting for indoor or outdoor high temperature alarm of cold
- High temperature alarm of industrial or commercial
- Outdoor temperature alarm of antifreeze
- High temperature alarm of green houses and livestock
Housing raw material | |
---|---|
Color | |
Ingress protection | |
Mechanical protection | |
Electrical rating | |
Voltage | |
Electrical life (cycles at rated value) | |
Measurement type | |
Sensing element | |
Setting adjustment |
Enclosure | Type | Operation | Contact | Measurement | Ranges °C | Models |
IP66, IK10 | Limiter | Electronic | SPNO or SPNC | Ambient | YF63NC & YF65NC | |
Material |
||||||
PA66 & PC |
Applications
– Equipment requesting a very strong resistance to water ingress. The transparent cover allows to visualize the set point and the 2 pilot lights.
- Wall mounting for indoor or outdoor high temperature alarm of cold
- High temperature alarm of industrial or commercial
- Outdoor temperature alarm of antifreeze
- High temperature alarm of green houses and livestock
Housing: Protection class IP 66 upon EN 60529 (waterproof spray water under high pressure and sea splashes, totally dust tight). Body in black PA66, fiber glass reinforced. The transparent polycarbonate cover can be unscrewed by hand, but it is also possible to use a hook spanner. Mechanical impact resistance : IK10. High UV resistance.
Set point adjustment: By °C printed knob. All types have an adjustable rotation limit system located inside the knob that allows reducing the set point adjustment span. °F printed knobs available as an option.
Operation: Microprocessor electronic thermostat,
Sensing element: NTC probe, mounted on the top of the plastic housing.
Pilot lights: One pilot light visualizes the thermostat contact output position. The other visualizes the power supply input. Phase and neutral electrical supply lines are mandatory for these pilot lights.
Set point adjustment ranges: -35-35°C (-30+95°F), 0-10°C (32-50°F), 4-40°C (40-105°F).
Reset: By push button switch beside the knob.
Cable input and output: Two M20 cable glands, built-in black PA66.
Electrical connections: Inside, on screw terminal connection block. It is possible to connect 2 wires 1.5mm² on each terminal.
Earthing: Internal screw terminal.
Mounting: Wall mounting, by 2 legs with holes for screws dia. 4 to 5 mm, 114 mm distance.
Identification: Identification label on backside
Contact: SPST. 16A (2.6), 250VAC. Open or close on temperature rise. Model with contact closing on temperature rise is used to switch on an alarm. Version with contact opening on temperature rise is used to switch off heating.
Electrical life: >100.000 cycles.
Minimum storage temperature: -35°C (-30°F)
Maximum ambient temperature: 60°C (140°F)
For more technical information ask 2PE2N6 thermostat technical data sheet.
Main references
Temperature adjustment ranges
°C (°F) |
References with SPNC, open on temperature rise contact | References with SPNO, close on temperature rise contact |
-35+35°C (-30+95°F) | YF63NC350350000J | YF65NC350350000J |
0+10°C (32-50°F) | YF63NC000100000J | YF65NC000100000J |
+4+40°C (40-105°F) | YF63NC040400000J | YF65NC040400000J |
Downloadable
Datasheets
Related products
Bulb and capillary temperature limiters
Pipe surface temperature limiter boxes
Manual reset electronic pipe mounting adjustable limiter IP65
Remote temperature limiter boxes
Manual reset electronic adjustable limiter, remote sensor, IP65
Pipe surface temperature limiter boxes
Room and antifreeze temperature control boxes
Remote temperature limiter boxes
Adjustable manual reset remote sensor electronic limiter IP66, IK10
Room and antifreeze temperature limiter boxes
Rod temperature control boxes
Technical informations associated to this product
-
Main properties of plastic raw materials used for enclosures
The classic housings, with only 5 sides and a lid, require a long and costly layout, most of the time ignoring the application needs: security, fire resistance, water penetration, shocks, UV, temperature, etc. -
Electrical protection classes
The housings are designed to protect electrical equipment located inside. This protection must be considered in the electrical and environmental angles.) -
Thermostats installation
The proper functioning of a thermostat depends primarily on the correct choice of the component, but also the conditions of its installation. Conditions used to calibrate regulating and control equipment in the factory are always ideal laboratory conditions, ensuring measurement accuracy and repeatability. These conditions are rarely those found in practice when installing thermostats. However, with a minimum of constraints, it is possible to optimize assemblies. -
Electrical contacts
As numerous mechanisms exist, we decided not to distinguish on the basis of constructive technique, but according to their operation speed, which is the key element.