Dia. 10mm cartridge thermostat 1/2″BSPT or M14x1.5 fitting, calibration from 50 to 120°C
Detection of a temperature value in liquids, water, hydraulic oils, thermal oils. Two versions of electrical contacts: Gold-plated for low power circuit, like PLC or 2A 250V for relay coils or resistive circuits.
Ingress protection | |
---|---|
Mechanical protection | |
Maximum pressure | |
Rod raw material | |
Fitting's thread | |
Sensor cable length (mm) | |
Contact Material | |
Electrical rating |
Applications
Detection of a temperature value in liquids, water, hydraulic oils, thermal oils. Two versions of electrical contacts: Gold-plated for low power circuit, like PLC or 2A 250V for relay coils or resistive circuits.
Main features
Probe material: 304 stainless steel sheath diameter 10mm, with AISI 304 fitting.
Calibration temperature: 50 to 120°C( 100 pcs MOQ applicable for specific values).
Tolerance on the opening temperature: ± 5°C
Fittings: 1/2 “BSPT (tapered) or M14x150 with gasket seat.
Immersed length (L1): Standard 90mm and 170mm (50, 230, 300mm on request)
Protection: IP65, IK10.
Pressure resistance: 25 bar.
Part sensitive to temperature: Located at the end of the sheath, on 35mm.
Contact: open by temperature rise. (Close on temperature rise possible on creep action models)
Electrical rating:
- PLC temperature alarm version: silver plated gold contact, creep action, 8A resistive in 12V/24V DC 60,000 cycles, differential less than 2°C.
- Thermal safety version: snap action silver contact, 2A, 250VAC, 100,000 cycles, differential higher than 10°C.
Cable outlet: 17x55mm PA66 overmolding.
Connection: H05VV F, 2 x 0.75 mm² cable, standard length 1m. (Connectors on cable end possible on request)
Main references with 1 meter cable (L2)
References with M14x1.5 thread and probe length =90mm | References with 1/2″BSPT thread and probe length =170mm | Open temperature | Rating |
72C14050E090H101 | 72C12050E170H101 | 50°C (122°F) | 8A 12-24VDC |
72C14070E090H101 | 72C12070E170H101 | 70°C (158°F) | 8A 12-24VDC |
72C14090E090H101 | 72C12090E170H101 | 90°C (194°F) | 8A 12-24VDC |
72C14110E090H101 | 72C12110E170H101 | 110°C (230°F) | 8A 12-24VDC |
72C14120E090H101 | 72C12120E170H101 | 120°C (248°F) | 8A 12-24VDC |
72J14050E090H101 | 72J12050E170H101 | 50°C (122°F) | 2A 250VAC |
72J14070E090H101 | 72J12070E170H101 | 70°C (158°F) | 2A 250VAC |
72J14090E090H101 | 72J12090E170H101 | 90°C (194°F) | 2A 250VAC |
72J14110E090H101 | 72J12110E170H101 | 110°C (230°F) | 2A 250VAC |
72J14120E090H101 | 72J12120E170H101 | 120°C (248°F) | 2A 250VAC |
Downloadable
Datasheet
Related products
Bimetal rod thermostats
Rod temperature control boxes
Rod temperature control boxes
Rod temperature control boxes
Rod temperature limiter boxes
Disc temperature limiters
Rod temperature limiter boxes
Rod temperature control boxes
High corrosion resistant electronic rod thermostat IP66, IK10
Technical informations associated to this product
-
Electrical contacts
As numerous mechanisms exist, we decided not to distinguish on the basis of constructive technique, but according to their operation speed, which is the key element. -
Electrical protection classes
The housings are designed to protect electrical equipment located inside. This protection must be considered in the electrical and environmental angles.) -
Temperature sensing principles
The bimetal strip is formed by two co-laminated metal. One has a high coefficient of expansion, the othera lower or zero. When the strip is heated, it bends proportionally to the temperature. These bimetal blades are generally flat and fixed at one end. But they can be wound in a spiral shape, although this arrangement most often used in the construction of thermometers. -
Important extracts of standards related to control or safety circuits
§3.8.1 All-pole cut out: Cutting in two conductors in a single operation, or for three phase units, the cut of the three conductors in a single step … Note: for three-phase, the neutral lead is not considered as a power conductor.