Big size enclosure with extension, for immersion heater, Y3M1
– Can accommodate 1″1/4, 1″1/2, M45x2, 2″, 2″1/2, and M77x2 double thread and internal nut fittings, or single thread with rotation ring
– Can receive one or more waterproof boots or screwed caps on the lid, allowing access to internal adjustment
– The cover can also receive multiple holes for pilot lights, switches, etc
Dimensions | 130 × 130 × 190 mm |
---|---|
Ingress protection | |
Housing raw material | |
Volume (cm³) |
Red dimensions inside rectangular frames on drawings are used for accessories assembly.
Main features
Big size enclosure with extension, for immersion heater
– Can accommodate 1″1/4, 1″1/2, M45x2, 2″, 2″1/2, and M77x2 double thread and internal nut fittings, or single thread with rotation ring
– Can receive one or more waterproof boots or screwed caps on the lid, allowing access to internal adjustment
– The cover can also receive multiple holes for pilot lights, switches, etc
– Can receive one or two power contactors on internal Din rail
– Features bosses and slides for PCBs
– Internal removable connection block (up to 12 ways, 2.5, 6 and 10mm²)
– Several models of cable gland plate holder, with many possibilities, including for flat cables, from 1 to 4 outlets, size up to M25
Size: 130 x 130 x 190 mm
Volume: 2836 cm³
Material: PA66
Ingress protection: IP69K
Mechanical impact resistance: IK10
Main references
A (mm) | B (mm) | C (mm) | D (mm) | References |
50 | 0 | 0 | 0 | Y3M150000000000T |
50 | 0 | 0 | 10 | Y3M1500A0000000T |
50 | 0 | 0 | 23.5 | Y3M1500D0000000T |
50 | 0 | 0 | M25×1.5 | Y3M1500F0000000T |
50 | 0 | 20 | 0 | Y3M150001200000T |
50 | 0 | 20 | 10 | Y3M1500A1200000T |
50 | 0 | 20 | 23.5 | Y3M1500D1200000T |
50 | 0 | 20 | M25×1.5 | Y3M1500F1200000T |
50 | 0 | 25 | 0 | Y3M150001250000T |
50 | 0 | 25 | 10 | Y3M1500A1250000T |
50 | 0 | 25 | 23.5 | Y3M1500D1250000T |
50 | 0 | 25 | M25×1.5 | Y3M1500F1250000T |
50 | 0 | M20×1.5 | 0 | Y3M150001T00000T |
50 | 0 | M20×1.5 | 10 | Y3M1500A1T00000T |
50 | 0 | M20×1.5 | 23.5 | Y3M1500D1T00000T |
50 | 0 | M20×1.5 | M25×1.5 | Y3M1500F1T00000T |
50 | 0 | M25×1.5 | 0 | Y3M150001T50000T |
50 | 0 | M25×1.5 | 10 | Y3M1500A1T50000T |
50 | 0 | M25×1.5 | 23.5 | Y3M1500D1T50000T |
50 | 0 | M25×1.5 | M25×1.5 | Y3M1500F1T50000T |
50 | 20 | 20 | 0 | Y3M150002200000T |
50 | 20 | 20 | 10 | Y3M1500A2200000T |
50 | 20 | 20 | 23.5 | Y3M1500D2200000T |
50 | 20 | 20 | M25×1.5 | Y3M1500F2200000T |
50 | 25 | 25 | 0 | Y3M150002250000T |
50 | 25 | 25 | 10 | Y3M1500A2250000T |
50 | 25 | 25 | 23.5 | Y3M1500D2250000T |
50 | 25 | 25 | M25×1.5 | Y3M1500F2250000T |
50 | M20×1.5 | M20×1.5 | 0 | Y3M150002T00000T |
50 | M20×1.5 | M20×1.5 | 10 | Y3M1500A2T00000T |
50 | M20×1.5 | M20×1.5 | 23.5 | Y3M1500D2T00000T |
50 | M20×1.5 | M20×1.5 | M25×1.5 | Y3M1500F2T00000T |
50 | M25×1.5 | M25×1.5 | 0 | Y3M150002T50000T |
50 | M25×1.5 | M25×1.5 | 10 | Y3M1500A2T50000T |
50 | M25×1.5 | M25×1.5 | 23.5 | Y3M1500D2T50000T |
50 | M25×1.5 | M25×1.5 | M25×1.5 | Y3M1500F2T50000T |
60 | 0 | 0 | 0 | Y3M160000000000T |
60 | 0 | 0 | 10 | Y3M1600A0000000T |
60 | 0 | 0 | 23.5 | Y3M1600D0000000T |
60 | 0 | 0 | M25×1.5 | Y3M1600F0000000T |
60 | 0 | 20 | 0 | Y3M160001200000T |
60 | 0 | 20 | 10 | Y3M1600A1200000T |
60 | 0 | 20 | 23.5 | Y3M1600D1200000T |
60 | 0 | 20 | M25×1.5 | Y3M1600F1200000T |
60 | 0 | 25 | 0 | Y3M160001250000T |
60 | 0 | 25 | 10 | Y3M1600A1250000T |
60 | 0 | 25 | 23.5 | Y3M1600D1250000T |
60 | 0 | 25 | M25×1.5 | Y3M1600F1250000T |
60 | 0 | M20×1.5 | 0 | Y3M160001T00000T |
60 | 0 | M20×1.5 | 10 | Y3M1600A1T00000T |
60 | 0 | M20×1.5 | 23.5 | Y3M1600D1T00000T |
60 | 0 | M20×1.5 | M25×1.5 | Y3M1600F1T00000T |
60 | 0 | M25×1.5 | 0 | Y3M160001T50000T |
60 | 0 | M25×1.5 | 10 | Y3M1600A1T50000T |
60 | 0 | M25×1.5 | 23.5 | Y3M1600D1T50000T |
60 | 0 | M25×1.5 | M25×1.5 | Y3M1600F1T50000T |
60 | 20 | 20 | 0 | Y3M160002200000T |
60 | 20 | 20 | 10 | Y3M1600A2200000T |
60 | 20 | 20 | 23.5 | Y3M1600D2200000T |
60 | 20 | 20 | M25×1.5 | Y3M1600F2200000T |
60 | 25 | 25 | 0 | Y3M160002250000T |
60 | 25 | 25 | 10 | Y3M1600A2250000T |
60 | 25 | 25 | 23.5 | Y3M1600D2250000T |
60 | 25 | 25 | M25×1.5 | Y3M1600F2250000T |
60 | M20×1.5 | M20×1.5 | 0 | Y3M160002T00000T |
60 | M20×1.5 | M20×1.5 | 10 | Y3M1600A2T00000T |
60 | M20×1.5 | M20×1.5 | 23.5 | Y3M1600D2T00000T |
60 | M20×1.5 | M20×1.5 | M25×1.5 | Y3M1600F2T00000T |
60 | M25×1.5 | M25×1.5 | 0 | Y3M160002T50000T |
60 | M25×1.5 | M25×1.5 | 10 | Y3M1600A2T50000T |
60 | M25×1.5 | M25×1.5 | 23.5 | Y3M1600D2T50000T |
60 | M25×1.5 | M25×1.5 | M25×1.5 | Y3M1600F2T50000T |
77 | 0 | 0 | 0 | Y3M177000000000T |
77 | 0 | 0 | 10 | Y3M1770A0000000T |
77 | 0 | 0 | 23.5 | Y3M1770D0000000T |
77 | 0 | 0 | M25×1.5 | Y3M1770F0000000T |
77 | 0 | 20 | 0 | Y3M177001200000T |
77 | 0 | 20 | 10 | Y3M1770A1200000T |
77 | 0 | 20 | 23.5 | Y3M1770D1200000T |
77 | 0 | 20 | M25×1.5 | Y3M1770F1200000T |
77 | 0 | 25 | 0 | Y3M177001250000T |
77 | 0 | 25 | 10 | Y3M1770A1250000T |
77 | 0 | 25 | 23.5 | Y3M1770D1250000T |
77 | 0 | 25 | M25×1.5 | Y3M1770F1250000T |
77 | 0 | M20×1.5 | 0 | Y3M177001T00000T |
77 | 0 | M20×1.5 | 10 | Y3M1770A1T00000T |
77 | 0 | M20×1.5 | 23.5 | Y3M1770D1T00000T |
77 | 0 | M20×1.5 | M25×1.5 | Y3M1770F1T00000T |
77 | 0 | M25×1.5 | 0 | Y3M177001T50000T |
77 | 0 | M25×1.5 | 10 | Y3M1770A1T50000T |
77 | 0 | M25×1.5 | 23.5 | Y3M1770D1T50000T |
77 | 0 | M25×1.5 | M25×1.5 | Y3M1770F1T50000T |
77 | 20 | 20 | 0 | Y3M177002200000T |
77 | 20 | 20 | 10 | Y3M1770A2200000T |
77 | 20 | 20 | 23.5 | Y3M1770D2200000T |
77 | 20 | 20 | M25×1.5 | Y3M1770F2200000T |
77 | 25 | 25 | 0 | Y3M177002250000T |
77 | 25 | 25 | 10 | Y3M1770A2250000T |
77 | 25 | 25 | 23.5 | Y3M1770D2250000T |
77 | 25 | 25 | M25×1.5 | Y3M1770F2250000T |
77 | M20×1.5 | M20×1.5 | 0 | Y3M177002T00000T |
77 | M20×1.5 | M20×1.5 | 10 | Y3M1770A2T00000T |
77 | M20×1.5 | M20×1.5 | 23.5 | Y3M1770D2T00000T |
77 | M20×1.5 | M20×1.5 | M25×1.5 | Y3M1770F2T00000T |
77 | M25×1.5 | M25×1.5 | 0 | Y3M177002T50000T |
77 | M25×1.5 | M25×1.5 | 10 | Y3M1770A2T50000T |
77 | M25×1.5 | M25×1.5 | 23.5 | Y3M1770D2T50000T |
77 | M25×1.5 | M25×1.5 | M25×1.5 | Y3M1770F2T50000T |
Cable gland not included in these reference, consult us if you want them.
To access download documents, please Login/Register. Datasheet, drawings (.dwg), 3D models (.stp) and other documents are available.
Downloads
Related products
Plastic housings
Technical informations associated to this product
-
Electrical protection classes
The housings are designed to protect electrical equipment located inside. This protection must be considered in the electrical and environmental angles.) -
Overview of immersion heater fittings
In Europe there are two common types of threads used on immersion heaters fittings. Threads according ISO 228-1, also said BSPP or cylindrical gas thread (G). 2mm pitch metric thread according ISO965-1, little used, which was the subject of an attempt to replace the ISO228-1 in the middle of the 20th -
Guide for immersion heater selection
Figures provided in this section are results of tests made in our laboratory. Charts were smoothened by computer, and are given for specified power and for information only. -
Main properties of plastic raw materials used for enclosures
The classic housings, with only 5 sides and a lid, require a long and costly layout, most of the time ignoring the application needs: security, fire resistance, water penetration, shocks, UV, temperature, etc.