Waterproof flat disc thermostat
Waterproof thermostat, can be incorporated inside thin heating devices, heating blankets, heating pads, antifreeze cables, electrical floor heating
Dimensions | 36.6 × 22 × 5.7 mm |
---|---|
Electrical rating | |
Opening temperature (°C) | |
Closing temperature (°C) | |
Wire lengths (mm) |
TECHNICAL FEATURES
Application: Waterproof thermostat, can be incorporated inside thin heating devices, heating blankets, heating pads, antifreeze cables, electrical floor heating
Electrical rating: 8A,125VAC res 4A, 250VAC res
Temperature calibration range: 0 to 120°C (32 to 248°F)
Contact: open or close on temperature rise
Differential: 8-15°C (46.4-59°F)
Tolerance: ±5°C on open and close
Contact resistance: < 70 mΩ (wires and optional TCO not included)
Insulation resistance: ≥ 100MΩ @500VDC
Thermal resistance: -20°C +130°C (except optional thermal fuse and wires)
Electrical life: ≥10.000 cycles under rated load
Wires: PVC insulated, 0.5 mm² (0.75 mm² on request), length 100, 200, 500, 1000 mm
Option: built-in thermal fuse, 2A, 5A or 8A.
Thermal fuse calibration must be at least 30°C higher than thermostat opening temperature (MOQ apply)
Main references
References | Open °C (°F) | Close °C (°F) | Wire lengths (mm) |
4N630101308JGCD0 | 13°C ±5°C (55.4 ±41°F) | 6°C±5°C (42.8±41°F) | 200 |
4N630103008JGCD0 | 30°C±5°C (86 ±41°F) | 22°C±5°C (71.6±41°F) | 200 |
4N630104008JGC10 | 40°C±5°C (104±41°F) | 32°C±5°C (89.6±41°F) | 1000 |
4N630105008JGC10 | 50°C±5°C (122±41°F) | 42°C±5°C (107.6±41°F) | 1000 |
Downloads
Related products
Disc thermostats
Bimetal surface thermostats
Bimetal rod thermostats
Bimetal surface thermostats
Dia. 10mm cartridge thermostat 1/2″BSPT or M14x1.5 fitting, calibration from 50 to 120°C
Bimetal rod thermostats
Technical informations associated to this product
-
Description of temperature controls
Used as control thermostats or as a safety thermostat with manual reset, these thermostats have a disc made of two different metals laminated together for temperature sensing element. These two metals have different expansion coefficients. -
Thermostats installation
The proper functioning of a thermostat depends primarily on the correct choice of the component, but also the conditions of its installation. Conditions used to calibrate regulating and control equipment in the factory are always ideal laboratory conditions, ensuring measurement accuracy and repeatability. These conditions are rarely those found in practice when installing thermostats. However, with a minimum of constraints, it is possible to optimize assemblies. -
Electrical protection classes
The housings are designed to protect electrical equipment located inside. This protection must be considered in the electrical and environmental angles.) -
Electrical contacts
As numerous mechanisms exist, we decided not to distinguish on the basis of constructive technique, but according to their operation speed, which is the key element.