3 pole manual reset disc thermostats
Temperature limit of heaters, instant water heaters, saunas steam generators, industrial heaters
Electrical rating | |
---|---|
Voltage | |
Max operating temperature (°C) | |
Opening temperature (°C) | 70, 75, 80, 85, 90, 95, 100, 105, 110, 120, 130, 140, 150, 160 |
Opening tolerance (°C) |
TECHNICAL FEATURES
Applications: Temperature limit of heaters, instant water heaters, saunas steam generators, industrial heaters
Housing dimensions: diameter 45mm, height 20mm (28mm with terminals),
Body material: high temperature PPS
Temperature sensing element: Bimetal disc
Terminals: 6.35 x 0.8mm quick connect
Set point temperature range: +20 to +180°C (Factory fixed setting only)
Mounting: surface mounting fixed bracket, 2 holes 4.4 x 6.4mm, 60 mm distance
Rating: 3 x 16A 250VAC, 3 x 10A 400VAC, resistive (10000 cycles) 3 x 25A 250VAC, 3 x 16A 400VAC (300 cycles)
Contact: 3 snap action contacts, double break, open on temperature rise.
Max ambient temperature: 180°C
Approvals: comply with EN 60730-1 and EN 60730-2 standards (CE mark)
Main references
References | Operating Temperature (°C/°F) | Tolerance (°C/°F) | References | Operating Temperature (°C/°F) | Tolerance (°C/°F) |
4C504T070RMEM60D | 70°C/158°F | ±4°C/±39.2°F | 4C504T105RMEM60D | 105°C/221°F | ±6°C/±42.8°F |
4C504T075RMEM60D | 75°C/167°F | ±4°C/±39.2°F | 4C504T110RMEM60D | 110°C/230°F | ±6°C/±42.8°F |
4C504T080RMEM60D | 80°C/176°F | ±5°C/±41°F | 4C504T120RMEM60D | 120°C/248°F | ±6°C/±42.8°F |
4C504T085RMEM60D | 85°C/185°F | ±5°C/±41°F | 4C504T130RMEM60D | 130°C/266°F | ±6°C/±42.8°F |
4C504T090RMEM60D | 90°C/194°F | ±5°C/±41°F | 4C504T140RMEM60D | 140°F/284°F | ±7°C/±44.6°F |
4C504T095RMEM60D | 95°C/203°F | ±5°C/±41°F | 4C504T150RMGM60D | 150°C/302°F | ±7°C/±44.6°F |
4C504T100RMEM60D | 100°C/212°C | ±5°C/±41°F | 4C504T160RMEM60D | 160°C/320°F | ±7°C/±44.6°F |
Downloads
Datasheet
Related products
Bulb and capillary thermostats
Disc thermostats
Bulb and capillary temperature limiters
Remote temperature limiter boxes
Explosion proof ATEX/IECEx temperature limiter boxes
Room and antifreeze temperature control boxes
Fixed setting ambiance or antifreeze thermostat, IP65 cable gland output, two pilot lights
Remote temperature limiter boxes
Adjustable manual reset remote sensor electronic limiter IP66, IK10
Disc temperature limiters
Technical informations associated to this product
-
Electrical contacts
As numerous mechanisms exist, we decided not to distinguish on the basis of constructive technique, but according to their operation speed, which is the key element. -
Electrical protection classes
The housings are designed to protect electrical equipment located inside. This protection must be considered in the electrical and environmental angles.) -
Description of temperature controls
Used as control thermostats or as a safety thermostat with manual reset, these thermostats have a disc made of two different metals laminated together for temperature sensing element. These two metals have different expansion coefficients. -
Thermostats installation
The proper functioning of a thermostat depends primarily on the correct choice of the component, but also the conditions of its installation. Conditions used to calibrate regulating and control equipment in the factory are always ideal laboratory conditions, ensuring measurement accuracy and repeatability. These conditions are rarely those found in practice when installing thermostats. However, with a minimum of constraints, it is possible to optimize assemblies.