3 pole pipe mounting temperature control thermostat IP65
Applications
Pipes surface temperature control in usual industrial applications and environments, to control 3 pole heating circuits (No suitable for hazardous areas)
Internal adjustment is convenient for products that must not be frequently adjusted.
Housing raw material | |
---|---|
Color | |
Ingress protection | |
Mechanical protection | |
Contact style | |
Contact Material | |
Electrical rating | |
Voltage | |
Electrical life (cycles at rated value) | |
Measurement type | |
Sensing element |
Enclosure | Type | Operation | Contact | Measurement | Ranges °C | Models |
IP65, IK10 | Control | Mechanical | 3PNC | Pipe | Y118C
& Y108C |
|
Material |
||||||
Aluminum |
Applications
Pipes surface temperature control in usual industrial applications and environments, to control 3 pole heating circuits (No suitable for hazardous areas)
Internal adjustment is convenient for products that must not be frequently adjusted.
Housing: Aluminum, IP65, IK10. Grey RAL7032 epoxy painting. Stainless steel captive cover screws. Captive aluminum lid. Set point adjustment ranges: 0-60°C (32-140°F); 0-90°C (32-195°F); 30-90°C (85-195°F); 30-110°C (85-230°F);
Set point adjustment: By °C printed knob. All types have an adjustable rotation limit system located inside the knob that allows reducing the set point adjustment span. Types with external adjustment have a transparent window. This device allows seeing the pilot light and the knob position. °F values are available as an option
Action: Temperature control, On-Off action
Sensing element: Liquid expansion bulb inside aluminum bracket in contact with the pipe surface.
The bracket design provides optimized thermal contact with 34 mm (1 “, DN25), 60 mm (2″, DN50) et 90 mm (3”, DN80) outside diameter tubes. For intermediate sizes, we recommend the use of thermal grease
Electrical connections: Inside, on screw terminal connection block
Earthing: External screw terminal.
Cable input and output: Two M20 cable glands, Black PA66.
Mounting: The thermostat housing can be fixed on the pipe by worm drive hose clamps (DIN3017) , nylon cable ties (Tie wraps upon EN50146, for applications at permanent temperature lower than 85°C), or specific stainless steel punched band (see accessories at the end of this catalog)
Identification: Metallic identification label, riveted.
Contact: 3PST, open on temperature rise
Electrical rating, resistive loads:
16A 250V, 50 ~60Hz: >100000 cycles,
20A 250V, 50 ~60Hz: ≥ 50000 cycles,
10A 400V, 50 ~60Hz: ≥ 50000 cycles.
Minimum storage temperature: -35°C (-30°F)
Maximum ambient temperature: 60°C (140°F)
For more technical information see 8C thermostat technical data sheet
Main references
Temperature adjustment ranges °C (°F) | Reference with external adjustment | Reference with internal adjustment | Differential °C (°F) | Max. temperature on tube
°C (°F) |
0-60°C (32-140°F) | Y118C000060AA80J | Y108C000060AA80J | 2.5±1°C (4,5±1,8F | 80°C (176°F) |
0-90°C (32-195°F) | Y118C000090AA80J | Y108C000090AA80J | 4±3°C (7±5.5 °F) | 120°C (250°F) |
30-90°C (85-195°F) | Y118C030090AA80J | Y108C030090AA80J | 4±3°C (7±5.5 °F) | 120°C (250°F) |
30-110°C (85-230°F) | Y118C030110AA80J | Y108C030110AA80J | 5±3°C (9±5.5 °F) | 150°C (300°F) |
Downloadable
Datasheet
Related products
Remote temperature control boxes
Disc temperature limiters
Bulb and capillary thermostats
Pipe surface temperature control boxes
Pipe surface temperature limiter boxes
Rod temperature control boxes
Room and antifreeze temperature control boxes
Rod temperature limiter boxes
Technical informations associated to this product
-
JPC Design concept of the Y1 types aluminum enclosures
Y1 range includes a wide range of thermostats in IP65* metal housing with high mechanical resistance (IK10** except models with external knob), intended for commercial or industrial applications covering ranges from -35 °C to +760 °C. -
Electrical contacts
As numerous mechanisms exist, we decided not to distinguish on the basis of constructive technique, but according to their operation speed, which is the key element. -
Electrical protection classes
The housings are designed to protect electrical equipment located inside. This protection must be considered in the electrical and environmental angles.) -
Thermostats installation
The proper functioning of a thermostat depends primarily on the correct choice of the component, but also the conditions of its installation. Conditions used to calibrate regulating and control equipment in the factory are always ideal laboratory conditions, ensuring measurement accuracy and repeatability. These conditions are rarely those found in practice when installing thermostats. However, with a minimum of constraints, it is possible to optimize assemblies.