Snap action disc thermostat, reduced height
9 mm reduced thickness ½”disc thermostat, 10A 250V
Weight | 0.3 kg |
---|---|
Dimensions | 20 × 20 × 20 mm |
Electrical rating | |
Bracket material |
Case: Phenolic resin (ceramic on request)
Sensing element: Bimetal disc
Calibration: Factory fixed setting, from -15 to +150°C, 5 to 302°F (200°C, 392°F with ceramic body). Not adjustable.
Standard calibration tolerances: ±4°C to ±6°C , ±39.2°F to 42.8°F upon models
Terminals: 6.3 or 4.8 quick connect , or welding terminals
Differential: Factory set, from 10°C to 25°C, 50°F to 77°F
Mounting: with or without bracket
Main bracket models:
- Loose bracket, two oval holes 3.2 x 3.5, for M3 screws, 24.5 mm distance
- Flat fixed bracket, two oval holes 3.2 x 3.5, for M3 screws, 24.5 mm distance
- Flat cup bracket, two oval holes 3.2 x 4.2, for M3 screws, 24 mm distance
- M4 or M5 center stud on request
Cap materials: stainless steel (SS) or aluminum (AL)
Ratings: 15A 125VAC, 10A 240VAC
Main bracket types
Main terminal types
Angle between terminals and bracket
MAIN REFERENCES (usually available from stock*)
* Products usually available from stock in one of the Ultimheat Alliance members ** Temperature in red= close on rise model *** Ceramic body
References
Open ** °C/°F
Tolerance ±°C/ ±°F
Close °C/°F
Tolerance ±°C/ ±°F
Bracket Nr
Bracket material
Terminal Nr
Angle terminal- bracket
4911NP03308CL6HF39
33/91.4
3/37.4
25/77
4/39.2
4
AL
B
90
4911SU04511CL6HF39
34/93.2
3/37.4
45/113
4/39.2
4
AL
B
90
4911SU04511CL6HM37
34/93.2
3/37.4
45/113
4/39.2
2
AL
B
N/A
4911NP03806CL6V037
38/100.4
3/37.4
32/89.6
4/39.2
1
AL
A
N/A
4911NP03806CCSV037
38/100.4
3/37.4
32/89.6
4/39.2
1
AL
E
N/A
4911NP03806CCSVM37
38/100.4
3/37.4
32/89.6
4/39.2
2
AL
E
N/A
4911NP04010DCSV037
40/104
3/37.4
30/86
4/39.2
1
AL
E
N/A
4911NP04010DCSVM37
40/104
3/37.4
30/86
4/39.2
2
AL
E
N/A
4911NP05010CL6HF39
50/122
3/37.4
40/104
4/39.2
4
AL
B
90
4911NP05010CL6H037
50/122
3/37.4
40/104
4/39.2
1
AL
B
N/A
4911NP05510DL6HF37
55/131
4/39.2
45/113
5/41
4
AL
B
90
4911NP06010CL6H037
60/140
3/37.4
50/122
4/39.2
1
AL
B
N/A
4911NP07010DL6H037
70/158
4/39.2
60/140
5/41
1
AL
B
N/A
4911NP07010DL6HF39
70/158
4/39.2
60/140
5/41
4
AL
B
90
4911NP07010DCSV037
70/158
4/39.2
60/140
5/41
1
AL
E
N/A
4911NP07010DCSVM37
70/158
4/39.2
60/140
5/41
2
AL
E
N/A
4911NP07510DCSV037
75/167
4/39.2
65/149
5/41
1
AL
E
N/A
4911NP07510DCSVM37
75/167
4/39.2
65/149
5/41
2
AL
E
N/A
4911NP08010DL6H037
80/176
3/37.4
70/158
4/39.2
1
AL
B
N/A
4911NP09015DCSVF39
90/194
4/39.2
75/167
5/41
4
AL
E
90
4911NP12514DL6VM37
125/257
5/41
111/231.8
6/42.8
2
AL
A
N/A
4911NP15023EL6VM37
150/302
6/42.8
141/285.8
7/44.6
2
AL
A
N/A
4910NP15514EL6VM37***
155/311
6/42.8
141/285.8
7/44.6
2
AL
A
N/A
These thermostats can be fitted inside various housings, overmolded and wired*. Some examples:
*These assemblies are made in the UL certified wiring harnesses production line of JPC
Downloads
Technical specifications sheet
Related products
Electromechanical humidistats
Rod temperature control boxes
Connection blocks
Bulb and capillary thermostats
Electronic control thermostats
Electronic thermostat, multi range, control and manual reset action, for incorporation, NTC sensor
Humidistat with ingress protection housings
Room and antifreeze temperature control boxes
Miniature room temperature thermostats wall mounting, home appliance style
Technical informations associated to this product
-
Thermostats types
It is currently the thermostats family where quantities are the most important. Numerous configurations exist, and the current trend is simplification and footprint reduction. -
Electrical contacts
As numerous mechanisms exist, we decided not to distinguish on the basis of constructive technique, but according to their operation speed, which is the key element. -
Thermostats installation
The proper functioning of a thermostat depends primarily on the correct choice of the component, but also the conditions of its installation. Conditions used to calibrate regulating and control equipment in the factory are always ideal laboratory conditions, ensuring measurement accuracy and repeatability. These conditions are rarely those found in practice when installing thermostats. However, with a minimum of constraints, it is possible to optimize assemblies. -
Heat tracing applications
To reflect the maximum temperatures allowed by the insulating polymers, the powers of flexible heating cables are generally between 5 and 30W/meter, exceptionally 40W/m and 60W/m for self-regulating cables.