ZC Low voltage circuit, IP65 waterproof differential pressure switch, various center threads
Use in areas where IP65 waterproofing is required. Medium positive, negative or differential pressure detection. Water level measurement, detection of clogging of water filters.Minimum water pressure detection on water heaters and boilers. This pressure switch is much more sensitive than snap-action systems and can be calibrated at lower pressures, but its use is limited to low power applications, typically on electronic circuits. Very low differential, less than 1 kPa (10 millibars, 0.15 PSI)
Fitting | Maximum Electrical rating | Minimum calibration pressure | Maximum calibration value | Type | |
PA66 | 1A 250VAC | 10 kPa
(100 mbar, 1.5 PSI) |
4 bar
(0.4 Mpa, 60 PSI) |
ZC | |
Main applications :
Use in areas where IP65 waterproofing is required. Medium positive, negative or differential pressure detection. Water level measurement, detection of clogging of water filters.Minimum water pressure detection on water heaters and boilers. This pressure switch is much more sensitive than snap-action systems and can be calibrated at lower pressures, but its use is limited to low power applications, typically on electronic circuits. Very low differential, less than 1 kPa (10 millibars, 0.15 PSI)
Membranes: Silicone, dia. 22mm.
Fluid: Water or air. (Connection of liquid on the negative pressure portis not allowed)
Fitting:
- Negative port by flexible PVC tube 3 x 6mm length 200mm (Other length on request)
- Positive port by ½” BSPT or NPT or ¼” BSPP thread in
Housing: PA66, UL94 VO, IP65 Ingress protection
Contact: Single pole normally open, slow make and break.
Electrical rating:
- Silver contact: max 1A 250VAC
- Gold plated contact: max 100mA, 24VDC
Action: Momentary, close on pressure rise on the positive port.
Set point calibration: Factory calibrated and sealed, not field adjustable
Set point calibration limits: From 10 to 400 kPa (100 to 4000 mbar, 1.5 to 60 PSI)
Electrical connection: PVC insulated cable, 2 x 0.2mm2 (AWG24)
Maximum pressure: 4 bar (0.4 Mpa, 60 PSI)
Bursting pressure: > 16 bar (1.6 Mpa, 232 PSI)
Electrical connection: AWG24 cable, UL 2464 style, length 500mm (other lengths on request}
Ambient temperature limits: water: 0 to 85°C (32 to 185°F), Air: -10 ~ 85°C (14 to 185°F)
Parts number (with 500mm cable and 300mm tube) :
Positive pressure port |
Contact |
Calibration | ||||
10 kPa
(100 mbar, 1.5 PSI) |
20 kPa
(200 mbar, 2.9 PSI) |
40 kPa
(400 mbar, 5.8 PSI) |
60 kPa
(600 mbar, 8.7 PSI) |
80 kPa
(800 mbar, 11.6 PSI) |
||
¼”” NPT | Silver | ZC2X28EA01000000 | ZC2X28EA02000000 | ZC2X28EA04000000 | ZC2X28EA06000000 | ZC2X28EA08000000 |
Gold plated | ZC2X28EG01000000 | ZC2X28EG02000000 | ZC2X28EG04000000 | ZC2X28EG06000000 | ZC2X28EG08000000 | |
¼”” BSPT | Silver | ZC2X2GEA01000000 | ZC2X2GEA02000000 | ZC2X2GEA04000000 | ZC2X2GEA06000000 | ZC2X2GEA08000000 |
Gold plated | ZC2X2GEG01000000 | ZC2X2GEG02000000 | ZC2X2GEG04000000 | ZC2X2GEG06000000 | ZC2X2GEG08000000 | |
M10x1 | Silver | ZC2X2MEA01000000 | ZC2X2MEA02000000 | ZC2X2MEA04000000 | ZC2X2MEA06000000 | ZC2X2MEA08000000 |
Gold plated | ZC2X2MEG01000000 | ZC2X2MEG02000000 | ZC2X2MEG04000000 | ZC2X2MEG06000000 | ZC2X2MEG08000000 | |
Snap-in | Silver | ZC2X2TEA01000000 | ZC2X2TEA02000000 | ZC2X2TEA04000000 | ZC2X2TEA06000000 | ZC2X2TEA08000000 |
Gold plated | ZC2X2TEG01000000 | ZC2X2TEG02000000 | ZC2X2TEG04000000 | ZC2X2TEG06000000 | ZC2X2TEG08000000 |
Downloads
Documents
Related products
Differential pressure switches
Medium pressure, slow action contact differential pressure switches, 6.35×0.8 mm terminals
Differential pressure switches
Medium pressure, slow action contact differential pressure switches, waterproof, IP65
Technical informations associated to this product
-
Absolute pressure, barometric pressure,negative pressure, differential pressure
Although pressure is an absolute value, the current measures pressure, are usually made relative to ambient air pressure. In other cases, the measurements are compared to vacuum. This leads to confusion and errors. -
Differences between air switches and pressure switches
Pressure switches are used to control the pressure of a medium and operate an electrical device. When pressure rises to the set point value, they switch off the equipment or switch on an alarm. Fluid they control can be air or water. There is no barometric or ambient temperature compensation in pressure switches. -
Important parameters to select a pressure switch
Accuracy, actuating force and differential are given by membrane surface. -
Technical foreword of elastomeric membrane pressure switches
The pressure switches of this catalogue are made according to the flexible elastomeric membrane technology. The pressure applied deforms the membrane which then actuates an electrical contact.